Cable Cervicom Interbus CHAIN Cable Chains

Bus cable with Polyurethane outer sheath for data transmission systems (Interbus) in industrial processes in dynamic installations, such as cable chains (horizontal installations)

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
Cable Cervicom Interbus CHAIN (Cable Chains)
~\ImgCli\no-foto.jpg
Bus cable with Polyurethane outer sheath for data transmission systems (Interbus) in industrial processes in dynamic installations, such as cable chains (horizontal installations)
Protegido electromagneticas
No propagador de la llama
Interbus
Flexible
Desina
Cadenas portacables
Resistente aceites
Construction
1. Conductor
Extra flexible bare copper wires
Cross sectional area: 0,25mm2
2. Insulation
Special compound
Identification: DIN 47100
(White+Brown, Green+Yellow, Grey+Pink)
3. Composition
Twisted pairs laid up together
4. Screen
Copper wire braid
5. Outer sheath
PUR (Polyurethane)
Colour: Violet according to DESINA
Technical characteristics
1. Operating voltage
250 V (Peak voltage) *NOT suitable for power applications with direct connection to the mains power supply network.
2. Test Voltage
1500 V (conductor-conductor)
1000 V (conductor-screen)
3. Operating Tª (conductor)
Fixed installation: -40°C +80°C
Dynamic installation: -30°C +70°C
4. Min. bending radius
Fixed installation: 10xD
Dynamic installation: 15xD
5. Loop resistance
159,8 Ohm/Km
6. Mutual capacitance
60 pF/m
7. Characteristic Impedance
120 Ohm ± 20% (64kHz)
100 Ohm ± 15% (1MHz)
8. Insulation resistance
1 GOhm*Km Min.
9. Attenuation (dB/100m)
1,5 at 0,256 MHz
2,4 at 0,772 MHz
2,7 at 1 MHz
5,2 at 4 MHz
8,4 at 10 MHz
11,2 at 16 MHz
11,9 at 20 MHz
Standards / Properties
1. Flame Retardant
VDE 0482, part 265-2-1 / IEC 60332-1
2. Other characteristics
Oil resistant
Abrasion resistant